{"product_id":"bd-367863-vacutainer-edta-blood-collection-tubes-6-ml-with-hemogard-closure-13mm-x-100mm-100-box","title":"EDTA Blood Collection Tubes BD Vacutainer 6 mL with Hemogard Closure 13mm x 100mm, 100\/box","description":"\u003cp\u003eEDTA Blood Collection Tubes are used mainly for hematology tests. The EDTA acts as an anticoagulant by binding calcium ions, preventing blood from clotting. These tubes are essential for:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Blood Count (CBC)\u003c\/strong\u003e: Evaluating red and white blood cells, hemoglobin, hematocrit, and platelets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlood Smears\u003c\/strong\u003e: Analyzing cell morphology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHemoglobin A1c\u003c\/strong\u003e: Monitoring glucose control over time in diabetic patients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlood Typing and Crossmatching\u003c\/strong\u003e: Preparing for blood transfusions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe anticoagulant properties of EDTA help maintain cellular integrity, leading to accurate hematological assessments.\u003c\/p\u003e\n\u003cp\u003eOptimize your hematology testing with BD Vacutainer EDTA Blood Collection Tubes, designed for precision and safety. These 6 mL tubes, featuring a Hemogard Closure, are essential for accurate and contamination-free sample collection, ensuring reliable results in laboratory diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetails and Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number\u003c\/strong\u003e: 367863\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize and Capacity\u003c\/strong\u003e: Each tube is 13mm x 100mm, with a 6 mL draw volume, ideal for a variety of laboratory tests.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eK2 EDTA Additive\u003c\/strong\u003e: Contains dipotassium ethylenediaminetetraacetic acid (K2 EDTA) as an anticoagulant to preserve blood cell morphology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHemogard™ Closure\u003c\/strong\u003e: Provides a secure seal to prevent leakage and reduces the risk of sample contamination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging\u003c\/strong\u003e: Comes in boxes of 100, perfect for high-volume laboratory environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanism of Action\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe K2 EDTA additive chelates calcium ions in the blood, effectively preventing coagulation. This ensures the preservation of cellular components, making it ideal for hematology assessments such as complete blood count (CBC).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDirections for Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation\u003c\/strong\u003e: Gather all necessary equipment and ensure the patient is prepared for blood draw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCollection\u003c\/strong\u003e: Perform venipuncture, allowing the tube to fill to the designated 6 mL volume to maintain correct blood-to-additive ratio.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixing\u003c\/strong\u003e: Immediately invert the tube 8-10 times to ensure proper mixing of blood with EDTA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing\u003c\/strong\u003e: Transport to the laboratory promptly, adhering to standard handling and storage protocols.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eWarnings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProper Volume\u003c\/strong\u003e: Ensure the tube is filled to the correct volume to guarantee accurate test results.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling and Disposal\u003c\/strong\u003e: Handle with care to avoid accidental needle sticks and dispose of sharps in appropriate containers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions\u003c\/strong\u003e: Store at temperatures between 4°C and 25°C, protecting from direct sunlight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Use\u003c\/strong\u003e: Intended for one-time use only. Do not attempt to reuse or sterilize.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Expiry\u003c\/strong\u003e: Use before the expiration date indicated on the packaging to ensure product effectiveness.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChoose BD Vacutainer EDTA Blood Collection Tubes for dependable and precise hematology testing. Renowned for their quality and safety, these tubes meet the demands of modern laboratories with excellence.\u003c\/p\u003e","brand":"BD","offers":[{"title":"Default Title","offer_id":53335193780542,"sku":"367863","price":4555.99,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/3408\/5182\/files\/EDTA-Blood-Collection-Tubes-BD-Vacutainer-6-mL.jpg?v=1776753228","url":"https:\/\/himkhand.com\/products\/bd-367863-vacutainer-edta-blood-collection-tubes-6-ml-with-hemogard-closure-13mm-x-100mm-100-box","provider":"Himkhand","version":"1.0","type":"link"}